Technical Data | |
Physical specifications | |
Screen | 5.4'' Display Screen |
Suitable | Adult & Child |
Mode | pneumatically powered and electrically controlled system |
Working Mode | Closed; Semi-Closed; Semi-Open |
Circuit | Breathing circuit integrated standards |
Tube | 4Tubes Flowmeters: O2:0.1~10L/Min, N2O:0.1~10L/Min |
Trolley | Fitted with 4 nos anti-static rubber castors; two of which are lockable for braking and easy maneuverability with foot operated |
brake provisions | |
Drawer unit | ONE drawer totally extractable |
Technical Specifications | |
Gas requirement | Medical oxygen and nitrous oxide with a pressure ranging from O2: 0.32~0.6MPa ; NO2: 0.32 MPa to 0.6 MPa. |
safety valve | <12.5 kPa |
Respiratory Rate | 1~99bpm |
Flow meter | O2:0.1~10L/Min, N2O:0.1~10L/Min |
oxygen concentration in the mixed gas N2O/O2 | > 21% |
Oxygen Flush | 25~75 L/min |
modes of ventilation | A/C, IPPV, SIPPV, IMV, SIMV, MANUAL |
I/E Ratio | 4:1 ~ 1:10, Has the inverse ratio ventilation |
Tidal Volume | 0~1500ML |
ptr inspiratory triggering pressure | -0.1kPa~1.0kPa |
Inspiratory Plateau | 0~1s |
O2 Concentration | 21%~100% |
Maximum safety pressure | ≤ 12.5 kPa |
Pressure limit range | 0 ~ 6.0 kPa |
Airway pressure alarm: Audible and visual and with yellow and red color indicating | Lower: 0.2kPa~5.0kPa; Upper: 0.3~6.0 kPa |
±0.2 kPa | |
Tidal volume alarm: Audible and visual and with yellow and red color indicating | upper alarm: 50 to 2000ml, lower alarm: 0~1800ml |
Power Supply Alarm | Ac/dc power supply are after failing to send out alarm immediately |
Alarm Time: keep >120s | |
The airway pressure continues to be higher than 15 hPa ±1 hPa for 15s±1s, then the machine will raise an audible alarm, the | |
pressure will be displayed in red and the continuous high pressure red alarm wording is displayed on the screen of the anesthetic | |
respirator. | |
Operating conditions | |
Ambient temperature: | 10 ~ 40oC |
Relative humidity: | no higher than 80 % |
Atmospheric pressure: | 860 hPa ~ 1060 hPa |
Power requirement: | 100-120 Vac, 50/60 Hz; |
Air source requirement: | Medical oxygen and gas with a rated pressure ranging from 0.3 to 0.5MPa. |
Attention: the AC power supply used for the anesthesia machine must be well grounded. | |
Attention: the anesthesia machine used must be equipped with a carbon dioxide monitor complying with ISO 9918:1993, an oxygen | |
monitor complying with ISO 7767:1997 and an expiratory gas volume monitor complying with 51.101.4.2 of Medical Electrical | |
Equipment Part II: Special Requirements for Safety and Basic Performance of Anesthesia System. | |
Storage | |
Ambient temperature: | -15oC ~ +50oC |
Relative humidity: | no higher than 95 % |
Atmospheric pressure: | 86 kPa ~ 106 kPa. |
It should be stored in a room without corrosive gas and well ventilated | |
Package | |
packaging box | comply with the requirement of GB/T 15464 |
Between the packaging box and product, soft material with appropriate thickness provided to prevent loosening and mutual friction | |
during transportation | |
Moisture protection and rain protection to ensure that product is protected from natural damage. | |
Safty & Alarm | |
Oxygen Alarm | It alarms when the oxygen supply from pipe or cylinders lower than 0.2MPa |
Ventilation Volume Alarm | Lower: 0~12L/Min; Up: 18L/ Min |
Power Alarm | It Alrmas while AC and DC supply failure ; Keep alraming time: >120s |
Air Tract Pressure Alarm | Lower: 0.2kPa ~5.0 kPa; Up: 0.3kPa ~ 6.0kPa |
STANDARD CONFIGURATIONS | |
QTY | NAME |
1 set | Main unit |
1 set | Built in ventilator |
1 set | 4 -tube flow meter |
2 set | vaporizer |
1 set | Patient circuit |
1 set | bellow |
1 set | Na lime tank |
1 set | Diaphragm electronic sensor |
1 pic | Oxygen pressure reducer |
2 pics | A leather bag ( Blue) |
4 pics | Threaded pipe |
2 pics | mask |
1 set | Tools with the machine |
1 set | User Manual (English Version) |
Optional | Patient Monitor |