Technical Specification |
|
Model |
AM-401 |
AM-301 |
AM-261 |
AM-161 |
Assay model |
Random access with direct reading system |
Method |
End point, Kinetic, Fixed time, Immunoturbidimetry, 1-2 reagent, Multi standard, reagent/serum blank, etc. |
Assay Item |
80 assay |
40 assays |
36 assay |
ISE mold (Na+ , K+ , Cl- /Li+) available on request |
Throughput |
1 Reagent |
400 tests/h |
300 tests/h(max) |
+240 tests/h |
+200 tests/h |
2 Reagent |
400 tests/h |
240 tests/h |
+150 tests/h |
+150 tests/h |
With ISE |
+120 tests/h |
+120 tests/h |
+120 tests/h |
+100 tests/h |
|
TBILI r-GT/GGT CHO Ca APOB-1/B CHE |
Test Menu |
|
D.BILI ALP/AKP TG CL APOB CREA |
|
|
TP UREA CK P CK-MB Mg |
|
|
ALB CREA LDH C ASO AFU |
|
|
Lactic Acid ALT/GPT UA α-HBDH CO2 FMN |
|
|
LP(a) AST/GOT GLU AMY LDL-C HDL-C |
|
|
CHE LA TBA ADA HS-CRP PA |
|
|
Fe Cu Zn C3 C4 LGG |
|
|
LGM LGA and drug, toxicity, etc. |
|
|
80 |
60 |
60 |
50 |
Sample position |
|
Including standard, control and stat; either serum cup or primary tube available |
|
Sample Volume |
1~100ul, 0.1ul/step |
Reagent Position |
2*40 |
40 or 80(optional) |
|
Reagent Volume |
R1:1~400ul, 1ul/step, R2: 1~400ul, 1ul/step |
Reagent/Sample probe |
With liquid level sensor, collision sensor, Teflon coating and automatic washing station. |
Reaction Time |
0~999 seconds |
Cuvette |
High quality UV-transmitted plastic cuvette. Quartz glass cuvettes available on request. |
Cuvette Washing |
8 channels automatic washing system for reaction cuvettes |
5 channels |
Probe and Mixer Washing |
Independent washing station for each sample/reagent probe and mixer |
Alarm |
Automatic alarm for malfunction (eg: collision, reagent/sample insufficiency, full waste container, etc.) |
Calibration |
Liner, Non-liner, Multi standard, K factor |
|
Sample can be diluted and retested if results are out of range or sample is insufficient. Also, with calibrator auto diluting |
Sample Dilution/Retest |
function |
Wavelength |
340~810nm |
Light Source |
Halogen lamp |
Absorbance Resolution |
0.0001A |
Absorbance Accuracy |
±0.0003A(0~2.5A) |
Repeatability (CV%) |
≤2% |
Quality Control |
Levy Jennings quality control program at 3 levels |
Bar Code |
Optional |
Printer |
Multiple report formats available |
Test Control Function |
New card control system available on request |
Language |
English, French, Spanish, German, Russian, etc. |
System |
Windows XP or Vista; Windows 7 |
Power Supply |
220V/50Hz or 110V/60Hz (optional) |
Dimension |
100*85*70(cm) |
85*72*53(cm) |
85*72*53(cm) |
65*53*52(cm) |
Weight |
137kg |
90kg |
85kg |